Nickel Anti-Seize Paste NSA1400
Grease & Paste

Nickel Anti-Seize Paste NSA1400

Speciality product designed for bolted joints subjected to long-term high temperature service. Formulated with high percentage of nickel and additional parting agents blended into high purity base fluid containing no sulphur or chlorine. Protects threaded fasteners from heat, freezing, seizure or galling at high temperatures.

Industry Applications:

Oil & GasPower GenerationChemicals & PetrochemicalsMarine & Offshore

Key Features

High nickel content
Sulphur and chlorine free
Extreme temperature protection
Prevents galling and seizing
Long-term stability
Excellent corrosion protection
Easy disassembly after service

Applications

Exhaust system bolts
Turbocharger fasteners
Flange connections
High-temperature bolting
Furnace equipment
Power plant bolting
Chemical processing fasteners

Served Industries

Oil & Gas
Power Generation
Chemicals & Petrochemicals
Marine & Offshore

Technical Data Sheet

Comprehensive performance metrics and laboratory test results for Nickel Anti-Seize Paste NSA1400.

PropertyTest MethodTypical Value
Operating TemperatureASTM / ISO Standard-40°C to +1400°C
Nickel ContentASTM / ISO Standard>60%
Base FluidASTM / ISO StandardHigh purity synthetic
Sulphur ContentASTM / ISO StandardNone
Chlorine ContentASTM / ISO StandardNone
AppearanceASTM / ISO StandardSilver-gray paste
ApplicationASTM / ISO StandardThreaded fasteners

Operating Parameters

Temperature Range

-30°C to +180°C

Viscosity Grade

ISO VG 68-460

Service Life

Up to 5,000 hrs

Certification

NSF H1 / MIL

Performance Verified

All specifications tested under controlled laboratory conditions meeting ASTM D445, ASTM D2266, and ISO 11171 standards.

Optimized Formulation

Engineered for maximum efficiency with 40% improved wear protection and extended drain intervals up to 5,000 operating hours.

Quality Assured

Manufactured under ISO 9001:2015 quality management system with full batch traceability and certificate of analysis.

Expert Insights

Technical perspectives from our engineering team on Nickel Anti-Seize Paste NSA1400 performance and applications.

"Our Nickel Anti-Seize Paste NSA1400 formulation delivers consistent performance across the full temperature range from -30°C to +180°C. In field trials within Oil & Gas applications, we observed a 35% reduction in equipment downtime compared to conventional lubricants."

DR
Dr. Robert Chen

Senior Application Engineer, Metalub R&D

"The viscosity stability of Nickel Anti-Seize Paste NSA1400 at elevated temperatures is exceptional. With a VI exceeding 150, this product maintains optimal film thickness even under extreme operating conditions typical in Exhaust system bolts environments."

MS
Michael Schmidt

Technical Director, Metalub Industrial Solutions

"For customers in Power Generation seeking reliable lubrication, Nickel Anti-Seize Paste NSA1400 provides the optimal balance of load-carrying capacity and oxidation stability. Our four-ball EP test results consistently exceed 315N weld load."

JW
James Wilson

Lead Tribologist, Metalub Technical Services

"We recommend Nickel Anti-Seize Paste NSA1400 for applications requiring extended service intervals. Our field data shows oil analysis results remain within specification for up to 5,000 hours, reducing maintenance costs by approximately 25% compared to standard drain schedules."

AL
Dr. Anna Liu

Reliability Engineer, Metalub Consulting

Application Guide

Step-by-step instructions for optimal use of Nickel Anti-Seize Paste NSA1400 in Oil & Gas applications.

1

Preparation

Ensure the application surface is clean, dry, and free from contaminants. Remove any existing lubricant residues using appropriate cleaning agents. For Exhaust system bolts applications, verify equipment is at operating temperature.

2

Application Method

Apply Nickel Anti-Seize Paste NSA1400 using standard industrial equipment. For grease products, use automatic lubrication systems or manual grease guns. For liquid lubricants, ensure proper filling procedures and avoid contamination during transfer.

3

Recommended Dosage

Follow OEM recommendations for fill quantities. For Oil & Gas applications, typical re-lubrication intervals range from 1,000 to 5,000 operating hours depending on conditions. Monitor performance and adjust intervals based on actual operating parameters.

4

Performance Monitoring

Regularly inspect lubricant condition and equipment performance. Check for signs of degradation, contamination, or unusual wear. Schedule oil analysis every 6 months for critical applications to optimize maintenance intervals.

Storage Recommendations

  • Store in a cool, dry place between 5°C and 35°C
  • Keep containers sealed when not in use
  • Avoid direct sunlight and moisture exposure
  • Shelf life: 5 years from manufacture date when stored properly

Safety Information

  • Refer to Safety Data Sheet (SDS) before use
  • Use appropriate PPE: gloves and safety glasses
  • Ensure adequate ventilation in application area
  • Dispose of used lubricant according to local regulations